EYC-Tech Airflow and Air Velocity Meters
EYC-Tech · Air Flow & Air Velocity
EYC-Tech OverviewEYC-Tech Air Flow & Air Velocity Meters
Thermal mass, differential pressure and hot-wire air flow and velocity transmitters for HVAC, compressed air, cleanroom and industrial duct applications, supplied by PCSPL with Australian support.
EYC-Tech Air Flow & Air Velocity Range
EYC-Tech Air Flow & Air Velocity Products
EYC-Tech FDM06-L
Bi-directional Low Air Flow Thermal Mass Transmitter
More product details
- Designed for laminar/overflow monitoring in cleanrooms and pharmaceutical facilities
- Sensor type: Hot-wire sensor; Turndown ratio: 100:1
- Measuring range: ±(0.00…1 m/s), ±(0.00…2 m/s), ±(0.00…10 m/s)
- Output: 4…20 mA / 0…10 V / Relay / RS-485
- Accuracy: ±(1% of mv + 0.05 m/s) to ±(1% of mv + 0.2 m/s)
- IP rating: IP65
EYC-Tech FDM06-I
Venturi Thermal Mass Flow Meter
More product details
- Unique Venturi tube structure — designed for compressed air systems
- Sensor type: Hot-wire sensor; Turndown ratio: 100:1
- Measuring range: 0…4,000 m³/h
- Output: 4…20 mA / 0…10 V / Relay / RS-485
- Accuracy: ±1.5% F.S.; IP rating: IP65
EYC-Tech FDM06-P
Average Flow Thermal Mass Transmitter
More product details
- Sensor type: Hot-wire sensor; Turndown ratio: 100:1
- Measuring range: 0.5…60 m/s
- Output: 4…20 mA / 0…10 V / Relay / RS-485
- Accuracy: ±(1.5% of mv + 0.8 m/s)
- IP rating: IP65
EYC-Tech FDM08
Venturi Inline Type Air Flow Transmitter
More product details
- Venturi inline type — wide range of applications
- Sensor type: Differential pressure sensor
- Air flow range: refer to airflow range table
- Output: 4…20 mA
- Accuracy: ±2%; IP rating: IP65 (housing)
EYC-Tech FTM06D-I
Inline Type Air Flow Transmitter
More product details
- Sensor type: Thermal mass flow sensor
- Measuring range: 0.1…848 m³/h
- Output: 4…20 mA / 0…10 V / RS-485 / Frequency / Pulse
- Accuracy: ±1.5% F.S.
- IP rating: IP65 (IP67 option)
EYC-Tech AFMP
Average Flow Measuring Tube (Pitot tube)
More product details
- Multi-point averaging — suitable for large pipes
- Resistant to high temperature and corrosion
- Standard type: max. 200°C, max. 10 bar
- High-temp. type: max. 600°C, max. 4 bar
- Length: 12″ (300 mm)
EYC-Tech FDM06S
Differential Pressure Type Air Flow Transmitter
More product details
- Bi-directional airflow measurement; calculates medium density and mass flow rate
- Sensor type: Differential pressure sensor
- Standard: ±(0.8…40 m/s); High-pressure: ±(20…200 m/s)
- Output: 4…20 mA / 0…10 V / Frequency / Pulse + RS-485
- Accuracy: ±1.5% F.S. (±1% F.S. option)
- IP rating: IP65 (body) / IP20 (probe head)
EYC-Tech FTE120-I
Inline Type Air Flow Transmitter
More product details
- Designed for pneumatic and compressed air systems; multiple diameters
- Sonic nozzles calibration
- Sensor type: Thermal mass flow sensor
- Measuring range: 0…1,500 l/min
- Output: 4…20 mA / 0…10 V / RS-485 / Frequency / Pulse
- Accuracy: ±2% F.S.; IP rating: IP65 (housing) / IP20 (probe)
EYC-Tech FTM94/95
Industrial High Accuracy Thermal Mass Flow Transmitter
More product details
- Air flow measurement up to 120 m/s
- Resistant to high temperature, high pressure, dust and corrosion
- Sensor type: Pt20/Pt300 (air velocity) / Pt1000 (temp.)
- Measuring range: 0…120 Nm/s
- Output: 4…20 mA / 0…10 V / RS-485 / Impulse
- Accuracy: ±1.5% F.S.; IP rating: IP67 (probe) / IP65 (housing)
EYC-Tech FTM84/85
Industrial High Accuracy Thermal Air Velocity Transmitter
More product details
- Suitable for clean air; resistant to high pressure and high temperature
- Sensor type: Thermal mass flow sensor
- Measuring range: 0…90 m/s
- Output: 4…20 mA / 0…10 V / RS-485
- Accuracy: ±1.5% F.S.; IP rating: IP67
EYC-Tech FTM06D
Thermal Mass Flow Transmitter
More product details
- Suitable for compressed dry air systems
- Sensor type: Thermal mass flow sensor
- Measuring range: 0…120 m/s
- Output: 4…20 mA / 0…10 V / RS-485 / Frequency / Pulse
- Accuracy: ±1.5% F.S.; IP rating: IP65
EYC-Tech FTE120
OEM Air Flow Transmitter
More product details
- Suitable for small-sized devices or equipment
- Compact size; various installation methods
- Sensor type: Thermal mass flow sensor
- Measuring range: 0…30 m/s
- Output: 4…20 mA / 0…10 V / RS-485
- Accuracy: ±2% F.S.; IP rating: IP65; MOQ: 50 pcs
EYC-Tech AFMT
Average Flow Measuring Tube (Pitot Static Tube)
More product details
- Multi-point averaging — suitable for large pipes
- Resistant to high temperature and corrosion
- Operating pressure: max. 10 bar
- Operating temperature: max. 250°C
- Length: 4″…40″ (100…1,000 mm)
EYC-Tech FTS140
Hot Wire Air Velocity Transmitter
More product details
- Economic model for HVAC application
- Sensor type: Hot wire mass flow transmitter
- Measuring range: 0…20 m/s
- Output: 4…20 mA / DC 0…10 V
- Accuracy: ±3% F.S.; IP rating: IP54
EYC-Tech FTS34/35
Air Velocity Transmitter
More product details
- Suitable for light industry; high accuracy and high stability
- Sensor type: Thermal mass flow sensor
- Measuring range: 0…40 m/s
- Output: 4…20 mA / DC 0…10 V
- Accuracy: ±2% F.S.; IP rating: IP54
EYC-Tech FTS07
Hot Wire Air Velocity Transmitter — Probe Type
More product details
- Probe type; easy to install; cost effective
- Sensor type: Hot wire mass flow transmitter
- Measuring range: 0…20 m/s
- Output: DC 0…10 V
- Accuracy: ±5% F.S.; IP rating: IP20; MOQ: 20 pcs
Need EYC-Tech Air Flow Product Support?
For product selection, datasheets or pricing on EYC-Tech air flow and air velocity transmitters, PCSPL is here to help with local Australian support.
📧 Contact PCSPL Today