EYC-Tech Airflow and Air Velocity Meters

EYC-Tech Air Flow & Air Velocity Meters | PCSPL
EYC-Tech Logo

EYC-Tech · Air Flow & Air Velocity

EYC-Tech Overview

EYC-Tech Air Flow & Air Velocity Meters

Thermal mass, differential pressure and hot-wire air flow and velocity transmitters for HVAC, compressed air, cleanroom and industrial duct applications, supplied by PCSPL with Australian support.

📅 Sourced from pcspl.au ⏱ Product range 🏷 EYC-Tech
Explore the EYC-Tech Air Flow & Air Velocity Meter range as supplied by PCSPL, including bi-directional low-flow thermal mass transmitters, Venturi inline and insertion meters, average flow pitot tubes, differential pressure type transmitters, hot-wire velocity transmitters and OEM sensors for HVAC, compressed air and industrial applications. Datasheets are linked below. For user manuals and other documentation, send your request to sales@pcspl.com.au.

EYC-Tech Air Flow & Air Velocity Products

EYC-Tech FDM06-L Bi-directional Low Air Flow Thermal Mass Transmitter

EYC-Tech FDM06-L

Bi-directional Low Air Flow Thermal Mass Transmitter

More product details
  • Designed for laminar/overflow monitoring in cleanrooms and pharmaceutical facilities
  • Sensor type: Hot-wire sensor; Turndown ratio: 100:1
  • Measuring range: ±(0.00…1 m/s), ±(0.00…2 m/s), ±(0.00…10 m/s)
  • Output: 4…20 mA / 0…10 V / Relay / RS-485
  • Accuracy: ±(1% of mv + 0.05 m/s) to ±(1% of mv + 0.2 m/s)
  • IP rating: IP65
Data Sheets
EYC-Tech FDM06-I Venturi Thermal Mass Flow Meter

EYC-Tech FDM06-I

Venturi Thermal Mass Flow Meter

More product details
  • Unique Venturi tube structure — designed for compressed air systems
  • Sensor type: Hot-wire sensor; Turndown ratio: 100:1
  • Measuring range: 0…4,000 m³/h
  • Output: 4…20 mA / 0…10 V / Relay / RS-485
  • Accuracy: ±1.5% F.S.; IP rating: IP65
Data Sheets
EYC-Tech FDM06-P Average Flow Thermal Mass Transmitter

EYC-Tech FDM06-P

Average Flow Thermal Mass Transmitter

More product details
  • Sensor type: Hot-wire sensor; Turndown ratio: 100:1
  • Measuring range: 0.5…60 m/s
  • Output: 4…20 mA / 0…10 V / Relay / RS-485
  • Accuracy: ±(1.5% of mv + 0.8 m/s)
  • IP rating: IP65
Data Sheets
EYC-Tech FDM08 Venturi Inline Type Air Flow Transmitter

EYC-Tech FDM08

Venturi Inline Type Air Flow Transmitter

More product details
  • Venturi inline type — wide range of applications
  • Sensor type: Differential pressure sensor
  • Air flow range: refer to airflow range table
  • Output: 4…20 mA
  • Accuracy: ±2%; IP rating: IP65 (housing)
Data Sheets
EYC-Tech FTM06D-I Inline Type Air Flow Transmitter

EYC-Tech FTM06D-I

Inline Type Air Flow Transmitter

More product details
  • Sensor type: Thermal mass flow sensor
  • Measuring range: 0.1…848 m³/h
  • Output: 4…20 mA / 0…10 V / RS-485 / Frequency / Pulse
  • Accuracy: ±1.5% F.S.
  • IP rating: IP65 (IP67 option)
Data Sheets
EYC-Tech AFMP Average Flow Measuring Tube Pitot tube

EYC-Tech AFMP

Average Flow Measuring Tube (Pitot tube)

More product details
  • Multi-point averaging — suitable for large pipes
  • Resistant to high temperature and corrosion
  • Standard type: max. 200°C, max. 10 bar
  • High-temp. type: max. 600°C, max. 4 bar
  • Length: 12″ (300 mm)
Data Sheets
EYC-Tech FDM06S Differential Pressure Type Air Flow Transmitter

EYC-Tech FDM06S

Differential Pressure Type Air Flow Transmitter

More product details
  • Bi-directional airflow measurement; calculates medium density and mass flow rate
  • Sensor type: Differential pressure sensor
  • Standard: ±(0.8…40 m/s); High-pressure: ±(20…200 m/s)
  • Output: 4…20 mA / 0…10 V / Frequency / Pulse + RS-485
  • Accuracy: ±1.5% F.S. (±1% F.S. option)
  • IP rating: IP65 (body) / IP20 (probe head)
Data Sheets
EYC-Tech FTE120-I Inline Type Air Flow Transmitter

EYC-Tech FTE120-I

Inline Type Air Flow Transmitter

More product details
  • Designed for pneumatic and compressed air systems; multiple diameters
  • Sonic nozzles calibration
  • Sensor type: Thermal mass flow sensor
  • Measuring range: 0…1,500 l/min
  • Output: 4…20 mA / 0…10 V / RS-485 / Frequency / Pulse
  • Accuracy: ±2% F.S.; IP rating: IP65 (housing) / IP20 (probe)
Data Sheets
EYC-Tech FTM94 FTM95 Industrial High Accuracy Thermal Mass Flow Transmitter

EYC-Tech FTM94/95

Industrial High Accuracy Thermal Mass Flow Transmitter

More product details
  • Air flow measurement up to 120 m/s
  • Resistant to high temperature, high pressure, dust and corrosion
  • Sensor type: Pt20/Pt300 (air velocity) / Pt1000 (temp.)
  • Measuring range: 0…120 Nm/s
  • Output: 4…20 mA / 0…10 V / RS-485 / Impulse
  • Accuracy: ±1.5% F.S.; IP rating: IP67 (probe) / IP65 (housing)
Data Sheets
EYC-Tech FTM84 FTM85 Industrial High Accuracy Thermal Air Velocity Transmitter

EYC-Tech FTM84/85

Industrial High Accuracy Thermal Air Velocity Transmitter

More product details
  • Suitable for clean air; resistant to high pressure and high temperature
  • Sensor type: Thermal mass flow sensor
  • Measuring range: 0…90 m/s
  • Output: 4…20 mA / 0…10 V / RS-485
  • Accuracy: ±1.5% F.S.; IP rating: IP67
Data Sheets
EYC-Tech FTM06D Thermal Mass Flow Transmitter

EYC-Tech FTM06D

Thermal Mass Flow Transmitter

More product details
  • Suitable for compressed dry air systems
  • Sensor type: Thermal mass flow sensor
  • Measuring range: 0…120 m/s
  • Output: 4…20 mA / 0…10 V / RS-485 / Frequency / Pulse
  • Accuracy: ±1.5% F.S.; IP rating: IP65
Data Sheets
EYC-Tech FTE120 OEM Air Flow Transmitter

EYC-Tech FTE120

OEM Air Flow Transmitter

More product details
  • Suitable for small-sized devices or equipment
  • Compact size; various installation methods
  • Sensor type: Thermal mass flow sensor
  • Measuring range: 0…30 m/s
  • Output: 4…20 mA / 0…10 V / RS-485
  • Accuracy: ±2% F.S.; IP rating: IP65; MOQ: 50 pcs
Data Sheets
EYC-Tech AFMT Average Flow Measuring Tube Pitot static tube

EYC-Tech AFMT

Average Flow Measuring Tube (Pitot Static Tube)

More product details
  • Multi-point averaging — suitable for large pipes
  • Resistant to high temperature and corrosion
  • Operating pressure: max. 10 bar
  • Operating temperature: max. 250°C
  • Length: 4″…40″ (100…1,000 mm)
Data Sheets
EYC-Tech FTS140 Hot Wire Air Velocity Transmitter

EYC-Tech FTS140

Hot Wire Air Velocity Transmitter

More product details
  • Economic model for HVAC application
  • Sensor type: Hot wire mass flow transmitter
  • Measuring range: 0…20 m/s
  • Output: 4…20 mA / DC 0…10 V
  • Accuracy: ±3% F.S.; IP rating: IP54
Data Sheets
EYC-Tech FTS34 FTS35 Air Velocity Transmitter

EYC-Tech FTS34/35

Air Velocity Transmitter

More product details
  • Suitable for light industry; high accuracy and high stability
  • Sensor type: Thermal mass flow sensor
  • Measuring range: 0…40 m/s
  • Output: 4…20 mA / DC 0…10 V
  • Accuracy: ±2% F.S.; IP rating: IP54
Data Sheets
EYC-Tech FTS07 Hot Wire Air Velocity Transmitter Probe Type

EYC-Tech FTS07

Hot Wire Air Velocity Transmitter — Probe Type

More product details
  • Probe type; easy to install; cost effective
  • Sensor type: Hot wire mass flow transmitter
  • Measuring range: 0…20 m/s
  • Output: DC 0…10 V
  • Accuracy: ±5% F.S.; IP rating: IP20; MOQ: 20 pcs
Data Sheets

Need EYC-Tech Air Flow Product Support?

For product selection, datasheets or pricing on EYC-Tech air flow and air velocity transmitters, PCSPL is here to help with local Australian support.

📧 Contact PCSPL Today