pH and Conductivity Probes: What to Check Before You Order

A practical PCSPL guide to choosing a pH and conductivity probe for process and water-treatment lines.

A pH and conductivity probe pair is often the first call on a water-treatment or dosing skid. pH tracks acidity; conductivity (or resistivity / TDS) tracks dissolved ionic strength. Wrong electrode chemistry, mount or transmitter means drift, fouling and short probe life. Here’s what to check before you order from the Sensorex, FIP/FLS, Barben and Aqua ranges PCSPL supplies.

What They Measure

pH Versus Conductivity on the Same Skid

pH electrodes report 0โ€“14 pH (FLS pH/ORP 200 also covers ORP ยฑ2000 mV). Conductivity sensors report ionic strength โ€” contacting cells for cleaner water, toroidal cells when coating would attack metal electrodes. The Sensorex TCS3020 toroidal sensor spans about 150 ยตS/cm to 2,000,000 ยตS/cm (Noryl, 105 ยฐC, 150 psig). The FLS M9.05 can display conductivity, resistivity or TDS and offers ultrapure-water temperature compensation.

The two readings answer different questions. pH tells you whether acid or caustic dosing is on target; conductivity tells you how much is dissolved overall, which is why it is the usual check on RO/EDI permeate, demineralised water, softener regeneration and cooling-tower blowdown. In ultrapure water (UPW) the reading is very low and temperature-sensitive, so compensation matters as much as the cell. In coating or high-solids streams the bigger risk is film build-up on the sensing surface, which is where toroidal cells earn their place.

Selection Checklist

What to Confirm Before You Order

Send these with the enquiry so we can match electrode, fitting and transmitter:

  • Liquid, temperature and pressure (FLS 200: to 7 bar at 25 ยฐC; 1 bar at 65 ยฐC)
  • Mounting: in-line tee, submersion, hot-tap / retractable, or flow cell
  • Output: raw mV, 4โ€“20 mA, Modbus, or a local display with relays
  • Fouling risk and calibration access
  • Whether ORP is required with pH
  • Low-conductivity water: Sensorex lists an S8000 cartridge for streams below 100 ยตS

Barben Performance Series sensors suit harsh duty and stay compatible with most major analysers. For cartridge change-out without rewiring, use the Sensorex S8000 system.

Pressure and access usually decide the mount. Barben lists in-line installation to 2,500 psig (172 bar), with Quick Change “Nut Lock” and retractable “Hot Tap” options to 300 psig (20 bar), so a sensor can come out without draining the line. On lighter duty, FLS 200 electrodes fit a simple reusable gland, an FLS tee or clamp saddle, and the CS150 can be submerged in a tank or mounted in-line (to 70 ยฐC and 7.5 bar).

Keeping the Reading Honest

Three Habits That Protect Probe Life

These habits match how the manufacturers expect the sensors to be used.

โš ๏ธ Calibrate on a schedule: Use fresh buffers and a two-point cal (Sensorex TX100 offers five buffer choices). A dirty or dry electrode will not hold it. The TX100 also stores calibration data through a power loss and shows a probe-cleaning reminder.
โš ๏ธ Keep the reference wet: Store pH probes in storage solution, not distilled water. A dry junction is the usual cause of slow response and offset. Double-junction references (FLS 200, S8000 cartridges) better tolerate streams that would poison a single junction.
โš ๏ธ Match the cell to the fouling: Prefer toroidal conductivity (TCS3020) or flat-glass pH tips where coating is likely; use contacting cells (e.g. Sensorex CS150, cell constant k = 0.1 or 1.0) on cleaner streams. Barben also offers coating-resistant and silica-resistant glass for difficult duty.

Range Snapshot

Which PCSPL Building Blocks Fit?

Start with the measurement and the signal your PLC or dosing pump needs.

๐Ÿงช

Sensorex S8000

Modular pH/ORP cartridges with quick change-out and EM modules for 4โ€“20 mA or Modbus; flat-glass, double-junction cartridges.

๐Ÿ“ก

Sensorex TX100

Loop-powered 4โ€“20 mA pH/ORP transmitter, NEMA 4X / IP65, with wall/panel/pipe/DIN mount and a clean reminder.

๐ŸŒ€

Sensorex TCS3020

Toroidal conductivity sensor in a Noryl body (ยพ″ MNPT) for dirty or coating-prone water, such as cooling towers and acid/base dilution.

๐Ÿ”ฉ

FIP/FLS pH/ORP 200

Epoxy-body electrodes for in-line or submersion on FLS fittings, single or double junction, DN15โ€“DN100.

๐Ÿ–ฅ๏ธ

FLS M9.05

Conductivity monitor with graphic display, dual 4โ€“20 mA, relays, USB setup, UPW compensation and a freely settable cell constant for two-electrode probes.

๐Ÿญ

Barben Performance Series

Industrial pH/ORP sensors with Axial Ion Pathยฎ reference for high pressure and poison resistance.

Datasheets: S8000 ยท TX100 ยท TCS3020 ยท FLS pH/ORP 200 ยท M9.05 ยท Barben ยท CS150. Pairing probes with dosing? See Peristaltic vs Diaphragm Dosing Pumps.

Talk to Us About a pH and Conductivity Probe

Send the liquid, temperature/pressure, mounting and required signal, and we’ll match electrodes, fittings and a transmitter to the duty.